Check short circuit
If the wire harness is ground shorted as in Fig. 5, locate the section by conducting a ”continuity check with ground”.

-
Continuity Check with Ground
-
Disconnect connectors (A) and (C) and measure the resistance between terminals 1 and 2 of connector (A) and body ground.
In the case of Fig. 6,
Between terminal 1 of connector (A) and body ground → Continuity
Between terminal 2 of connector (A) and body ground → No continuity (open)
Therefore, it is found out that there is a short circuit between terminal 1 of connector (A) and terminal 1 of connector (C). -
Disconnect connector ”B” and measure the resistance between terminal 1 of connector ”A” and body ground, and terminal 1 of connector ”B2” and body ground.
Between terminal 1 of connector ”A” and body ground → No continuity
Between terminal 1 of connector ”B2” and body ground → Continuity (short)
Therefore, it is found out that there is a short circuit between terminal 1 of connector ”B2” and terminal 1 of connector ”C”.
-
Disconnect connectors (A) and (C) and measure the resistance between terminals 1 and 2 of connector (A) and body ground.

This guide is based on the book edition Toyota (RM502U, 1997)
Volksbibliothek, info@volksbibliothek.com
Back Next